Ultraviolet Disinfection Unit For Small

and Medium Spaces

High-power disinfection

Our products for air purification offer the same protection and effectiveness as our solutions for surface disinfection, but in the effective control of the aerosols, which are particularly often discussed.

They are designed for different room sizes and dimensioned in such a way that they meet all your requirements in terms of the degree of purification of the air, the circulation per hour or the operating noise. Only use air purifiers when they are really needed. Do not create sterile environments through 24/7 operation. This saves electricity and there is no unnecessary annual replacement of the UV-C tubes.

The areas of application are endless. Meeting rooms, trade fairs and conference centers, waiting rooms, lecture halls, classrooms, fitness studios, public transport, recording studios, rehearsal rooms, etc.

In addition, our air purification products are designed in such a way that by removing three flaps the device can be converted into a surface disinfection lamp with all its safety features.

Fight Covid-19 in a variety of ways. During the meeting in air mode, after the meeting to disinfect the surfaces quickly and safely.

 

30
30
MINUTES
60 M²
60
60
MINUTES
120 M²
120
120
MINUTES
240 M²

 

 

What is UV and UVC?

Ultraviolet light is a form of radiation and an invisible part of the electromagnetic spectrum. It has a wavelength between 100nm-380nm. UVC with a wavelength of 200nm-280nm has proved to be the most effective disinfectant wavelength in the UV Spectrum. As we all know UV Light is also found in sunlight.

GUVI uses the ultraviolet spectral wavelength 253.7nm. This belongs to the short-wave UVC spectrum and is an efficient and better choice for disinfection!

Technical Specifications
Product:
  • Ultraviolet Air and Surface Purification/Disinfection Unit

Light Source - W
  • 36Wx6

Light Source Lifespan
  • Max.9,000h

Voltage:
  • 100~240VAC 50/60Hz

Control:
  • Touch keys

Main Material:
  • Anti-UV organic glass

Function:
  • UV disinfection
Wavelength:
  • 253.7nm

Cable Length:
  • 1.8m

Compliance:
  • CE, ETL, FCC

Application:
  • Small to medium size rooms: office, workshop, hotel, small theater and other public places

 

Features
  • Safety By Design - A motion sensor will detect any movement within 3 meters and immediately deactivate the lamp and sound an alarm.

  • Safe Start - 3 minutes delayed start with audible alarms Once the disinfection time is set, the lamp will be turned on after a delay of 3 minutes allowing people and pets to leave the room.

  • Fall Protection - Auto Power Off - When lamp detects a movement of more than 45°, it will automatically power off, thus preventing heat damage to surrounding objects, should the lamp fall over.

  • No Ozone - Safe and harmless – Leave no residue, Note: Only when used in accordance with manufacturer instructions

  • High Quality Lamp

  • Integrated Wheels: Allows fast and easy relocation of unit
Warning

Ultraviolet light can cause damage to eyes and skin. All personnel, animals and plants must leave/ be moved from the site during use.

 

Precautions
  • Ultraviolet disinfection lamp products emitting UV-C at 253.7nm must only be used in an environment with no living things present (humans, animals, plants). Ultraviolet light may cause skin redness, itching, peeling, and eye conjunctive damage caused by electro-optical ophthalmitis. Never look directly at the lamp without suitable eye protection when it is powered on and emitting light. It is essential that all people and pets leave the room before the lamp is turned on and only re-enter the room after the lamp has been turned off/ has finished its disinfection cycle.

  • Ultraviolet has a degrading effect on many materials including plastics, paper and cloth. Exposure to irradiation over long periods of time may cause the surface of the irradiated objects to change color and or become more brittle. Never use ultraviolet sterilization lamp products emitting direct irradiation on expensive clothing, ornaments, calligraphy, painting and other valuables.

  • The surface of the lamp tube should be kept clean when using the UV disinfection lamp. It is recommended to clean the lamp tube regularly when not in use (usually every 2 weeks). When cleaning, please use a soft clean cotton cloth with a small amount of alcohol to wipe the lamp tube surface, remove the dust and oil.

  • A side effect of disinfection can be an abnormal smell, similar to that of the sun drying wet bedding, we recommend that spaces are well ventilated for 10-15 minutes following disinfection.

  • UV lamps should be properly protected after disinfection and placed out of reach of children, in a safe place.

  • Impact and strong vibration may cause the lamp tube to break. Should the lamp tube break, immediately turn off the power supply and dispose of the lamp, wearing protective gloves and according to your local toxic and harmful garbage rules. Should a lamp break, immediately open the windows for 10-15 minutes of ventilation.

  • Never disinfect areas with inflammable or explosive items as you may otherwise cause burning or explosion.

  • If the lamp tube needs to be replaced, replace only with the original brand of lamp tube and complete the operation according to the procedures in the user manual.